4.7 Article

A novel magnetic ionic liquid modified carbon nanotube for the simultaneous determination of aryloxyphenoxy-propionate herbicides and their metabolites in water

期刊

ANALYTICA CHIMICA ACTA
卷 852, 期 -, 页码 88-96

出版社

ELSEVIER
DOI: 10.1016/j.aca.2014.09.024

关键词

Ionic liquid modified carbon nanotube; Dispersive magnetic solid-phase extraction; Aryloxyphenoxy-propionate herbicide; Metabolites

资金

  1. Program for New Century Excellent Talents in University [NCET09-0738]
  2. National Natural Science Foundation of China [21277171, 21337005, J1210064]
  3. Foundation for the Author of National Excellent Doctoral Dissertation of PR China
  4. New-Star of Science and Technology - Beijing Metropolis
  5. Program for New Century Excellent Talents in University
  6. Program for Changjiang Scholars and Innovative Research Team in University

向作者/读者索取更多资源

A reliable, sensitive, rapid and environmentally friendly analysis procedure for the simultaneous determination of the analytes with a wide range of polarity in the environmental water was developed by coupling dispersive magnetic solid-phase extraction (d-MSPE) with high-performance liquid chromatography (HPLC)-diode array detector (DAD) and ultra-high pressure liquid chromatography (UHPLC)-triple quadrupole mass spectrometer (MS/MS), in this work. Magnetic ionic liquid modified multi-walled carbon nanotubes (m-IL-MWCNTs) were prepared by spontaneous assembly of magnetic nanoparticles and imidazolium-modified carbon nanotubes, and used as the sorbent of d-MSPE to simultaneously extract aryloxyphenoxy-propionate herbicides (AOPPs) and their polar acid metabolites due to the excellent p-p electron donor-acceptor interactions and anion exchange ability. The factors, including the amount of sorbent, pH of the sample solution, extraction time and the volume of elution solvent were investigated. Under the optimized conditions, the proposed d-MSPE coupling to HPLC-DAD system had a satisfactory performance, the limits of detection (LODs, defined as the signal to noise ratio of 3) and the limits of quantification (LOQs, defined as the signal to noise ratio of 10) for analytes in Milli-Q water were in the range of 2.8-14.3 and 9.8-43.2 mu g L-1 respectively. Calibration curves were linear (r(2) > 0.998) over the concentration range from 0.02 to 1 mu g L-1. The recoveries of the eight analytes ranged from 66.1 to 89.6% with the RSDs less than 8.6%. In order to extend the method in extremely low concentration analysis, d-MSPE-UHPLC-MS/MS was investigated, which showed better performance in terms of limit of detection and analysis time. (C) 2014 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据