4.7 Article

Polythiophene-coated Fe3O4 superparamagnetic nanocomposite: Synthesis and application as a new sorbent for solid-phase extraction

期刊

ANALYTICA CHIMICA ACTA
卷 770, 期 -, 页码 68-74

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.aca.2013.01.043

关键词

Polythiophene-coated Fe3O4 magnetic nanoparticles; Magnetic separation; Phthalates; Gas chromatography-flame ionization detector; Solid-phase extraction

资金

  1. Tarbiat Modares University
  2. National Elites Foundation, Iran

向作者/读者索取更多资源

In the present work, a novel type of superparamagnetic nanosorbent, polythiophene-coated Fe3O4 nanoparticles (Fe3O4@PTh NPs), have been successfully synthesized. The synthesized NPs were characterized by scanning electron microscopy (SEM), Fourier transform-infrared (FT-IR) spectroscopy, and thermal gravimetric analysis (TGA). The synthesized Fe3O4@PTh NPs were applied as an efficient sorbent for extraction and preconcentration of several typical plasticizer compounds (di-n-butyl phthalate (DBP), di-(2-ethylhexyl) phthalate (DEHP), and dioctyl adipate (DOA)) from environmental water samples. Separation of Fe3O4@PTh NPs from the aqueous solution was simply achieved by applying external magnetic field. Separation and determination of the extracted plasticizers was performed by gas chromatography-flame ionization detection (GC-FID). Several variables affecting the extraction efficiency of the analytes i.e., amount of NPs sorbent, salt concentration, extraction time, and desorption conditions were investigated and optimized. The best working conditions were as follows: amount of sorbent, 100 mg; NaCl concentration, 30% (w/v); sample volume, 45 mL; extraction time, 10 min; and 100 mu L of ethyl acetate for desorption of the analytes within 2 min. Under optimized conditions, preconcentration factors for DBP, DEHP, and DOA were obtained as 86,194, and 213, respectively. The calibration curves were linear (R-2 > 0.998) in the concentration range of 0.4-100 mu g L-1 for both DEHP and DOA and 0.7-100 mu g L-1 for DBP. The limits of detection (LODs) were obtained in the range of 0.2-0.4 mu g L-1. The intra-day relative standard deviations (RSDs%) based on four replicates were obtained in the range of 4.0-12.3%. The proposed procedure was applied to analysis of water samples including river water, bottled mineral water, and boiling water exposed to polyethylene container (after cooling) and recoveries between 85 and 99% and RSDs lower than 12.8% were obtained. (C) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据