4.7 Article

Selective optical sensing of biothiols with Ellman's reagent: 5,5′-Dithio-bis(2-nitrobenzoic acid)-modified gold nanoparticles

期刊

ANALYTICA CHIMICA ACTA
卷 794, 期 -, 页码 90-98

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.aca.2013.07.041

关键词

Biothiols; Conventional 5,5 '-dithio-bis(2-nitrobenzoic acid) (DTNB) assay; Gold nanoparticles; Optical sensor; HPLC

资金

  1. Istanbul University Research Fund, Bilimsel Arastirma Projeleri (BAP) Yurutucu Sekreterligi
  2. Ministry of Development for the Advanced Research Project of Istanbul University [2011K120320]
  3. [T-26308]

向作者/读者索取更多资源

Development of sensitive and selective methods of determination for biothiols is important because of their significant roles in biological systems. We present a new optical sensor using Ellman's reagent (DTNB)-adsorbed gold nanoparticles (Au-NPs) (DTNB-Au-NP) in a colloidal solution devised to selectively determine biologically important thiols (biothiols) from biological samples and pharmaceuticals. 5,5'-Dithio-bis(2-nitrobenzoic acid) (DTNB), a versatile water-soluble compound for quantitating free sulfhydryl groups in solution, was adsorbed through non-covalent interaction onto Au-NPs, and the absorbance changes associated with the formation of the yellow-colored 5-thio-2-nitrobenzoate (TNB2-) anion as a result of reaction with biothiols was measured at 410 nm. The sensor gave a linear response over a wide concentration range of standard biothiols comprising cysteine, glutathione, homocysteine, cysteamine, dihydrolipoic acid and 1,4-dithioerythritol. The calibration curves of individual biothiols were constructed, and their molar absorptivities and linear concentration ranges determined. The cysteine equivalent thiol content (CETC) values of various biothiols using the DTNB-Au-NP assay were comparable to those of the conventional DTNB assay, showing that the immobilized DTNB reagent retained its reactivity toward thiols. Common biological sample ingredients like amino acids, flavonoids, vitamins, and plasma antioxidants did not interfere with the proposed sensing method. This assay was validated through linearity, additivity, precision and recovery, demonstrating that the assay is reliable and robust. DTNB-adsorbed Au-NPs probes provided higher sensitivity (i.e., lower detection limits) in biothiol determination than conventional DTNB reagent. Under optimized conditions, cysteine (Cys) was quantified by the proposed assay, with a detection limit (LOD) of 0.57 mu M and acceptable linearity ranging from 0.4 to 29.0 mu M (r = 0.998). (C) 2013 Elsevier B. V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据