4.7 Article

Sensitivity of microarray based immunoassays using surface-attached hydrogels

期刊

ANALYTICA CHIMICA ACTA
卷 781, 期 -, 页码 72-79

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.aca.2013.04.013

关键词

Protein microarray; Immunoassay; Fluorescence measurement; Hydrogel; Dynamic range

资金

  1. BMWi-AIF [KF2162015MD1]

向作者/读者索取更多资源

A promising pathway to improve on the sensitivity of protein microarrays is to immobilize the capture antibodies in a three dimensional hydrogel matrix. We describe a simple method based on printing of an aqueous protein solution containing a photosensitive polymer and the capture antibody onto a plastic chip surface. During short UV-exposure photocrosslinking occurs, which leads to formation of a hydrogel, which is simultaneously bound to the substrate surface. In the same reaction the antibody becomes covalently attached to the forming hydrogel. As the capture antibodies are immobilized in the three-dimensional hydrogel microstructures, high fluorescence intensities can be obtained. The chip system is designed such, that non-specific protein adsorption is strongly prevented. Thus, the background fluorescence is strongly reduced and very high signal-to-background ratios are obtained (SBR > 6 for C-BSA = 1 PM; SBR > 100 for C-BSA > 100pM). The kinetics of antigen binding to the arrayed antibodies can be used to determine the concentration of a specific protein (for example the tumor marker beta(2)-microglobulin) in solution for a broad range of analyte concentrations. By varying size and composition of the protein-filled hydrogel microstructures as well as adjusting the extent of labeling it is possible to easily adapt the surface concentration of the probe molecules such that the fluorescence signal intensity is tuned to the prevalence of the protein in the analyte. As a consequence, the signal tuning allows to analyze solutions, which contain both proteins with high (here: upper mg ml(-1) range) and with very low concentrations (here: lower mu g mL(-1) range). This way quantitative analysis with an exceptionally large dynamic range can be performed. (C) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据