4.6 Article

Determination of triazine herbicides in aqueous samples by dispersive liquid-liquid microextraction with gas chromatography-ion trap mass spectrometry

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1161, 期 1-2, 页码 89-97

出版社

ELSEVIER
DOI: 10.1016/j.chroma.2007.05.065

关键词

dispersive liquid-liquid microextraction (DLLME); sample preparation; water samples analysis; gas chromatography-ion trap mass spectrometry (GC-MS); triazine herbicides

向作者/读者索取更多资源

A simple and rapid new dispersive liquid-liquid microextraction technique (DLLME) coupled with gas chromatography-ion trap mass spectrometric detection (GC-MS) was developed for the extraction and analysis of triazine herbicides from water samples. In this method, a mixture of 12.0 mu L chlorobenzene (extraction solvent) and 1.00 mL acetone (disperser solvent) is rapidly injected by syringe into the 5.00 mL water sample containing 4% (w/v) sodium chloride. In this process, triazines in the water sample are extracted into the fine droplets of chlorobenzene. After centrifuging for 5 min at 6000 rpm, the fine droplets of chlorobenzene are sedimented in the bottom of the conical test tube (8.0 +/- 0.3 mu L). The settled phase (2.0 mu L) is collected and injected into the GC-MS for separation and determination of triazines. Some important parameters, viz, type of extraction solvent, identity and volume of disperser solvent, extraction time, and salt effect, which affect on DLLME were studied. Under optimum conditions the enrichment factors and extraction recoveries were high and ranged between 151-722 and 24.2-115.6%, respectively. The linear range was wide (0.2-200 mu g L-1) and the limits of detection were between 0.021 and 0. 12 mu g L-1 for most of the analytes. The relative standard deviations (RSDs) for 5.00 mu g L-1 of triazines in water were in the range of 1.36-8.67%. The performance of the method was checked by analysis of river and tap water samples, and the relative recoveries of triazines from river and tap water at a spiking level of 5.0 mu g L-1 were 85.2-114.5% and 87.8-119.4%, respectively. This method was also compared with solid-phase microextraction (SPME) and hollow fiber protected liquid-phase microextraction (HFP-LPME) methods. DLLME is a very simple and rapid method, requiring less than 3 min. It also has high enrichment factors and recoveries for the extraction of triazines from water. (c) 2007 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据