4.7 Article

Impedimetric immunosensor for human serum albumin detection on a direct aldehyde-functionalized silicon nitride surface

期刊

ANALYTICA CHIMICA ACTA
卷 720, 期 -, 页码 43-48

出版社

ELSEVIER
DOI: 10.1016/j.aca.2012.01.031

关键词

Immunosensor; Silicon nitride; Aldehyde; Electrochemical impedance spectroscopy; Human serum albumin

资金

  1. European Communities [248763]
  2. DVT-IMP [EUR STREPT 34256]
  3. NATO [CBP.NUKR.CLG 982955]
  4. CIBER Actions
  5. Institut de Salud Carlos III
  6. European Regional Development Fund
  7. Spanish Ministry of Science and Education
  8. Commission for Universities and Research of the Department of Innovation, Universities
  9. Enterprise of the Generalitat de Catalunya [2009 SGR 505]
  10. Fundacion M. Botin, Santander, Spain

向作者/读者索取更多资源

In this work we report the fabrication and characterization of a label-free impedimetric immunosensor based on a silicon nitride (Si3N4) surface for the specific detection of human serum albumin (HSA) proteins. Silicon nitride provides several advantages compared with other materials commonly used, such as gold, and in particular in solid-state physics for electronic-based biosensors. However, few Si3N4-based biosensors have been developed; the lack of an efficient and direct protocol for the integration of biological elements with silicon-based substrates is still one of its the main drawbacks. Here, we use a direct functionalization method for the direct covalent binding of monoclonal anti-HSA antibodies on an aldehyde-functionalized Si-p/SiO2/Si3N4 structure. This methodology, in contrast with most of the protocols reported in literature, requires less chemical reagents, it is less time-consuming and it does not need any chemical activation. The detection capability of the immunosensor was tested by performing non-faradaic electrochemical impedance spectroscopy (EIS) measurements for the specific detection of HSA proteins. Protein concentrations within the linear range of 10(-13)-10(-7) M were detected, showing a sensitivity of 0.128 Omega mu M-1 and a limit of detection of 10(-14) M. The specificity of the sensor was also addressed by studying the interferences with a similar protein, bovine serum albumin. The results obtained show that the antibodies were efficiently immobilized and the proteins detected specifically, thus, establishing the basis and the potential applicability of the developed silicon nitride-based immunosensor for the detection of proteins in real and more complex samples. (C) 2012 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据