4.7 Article

Dendrimer-rhodium nanoparticle modified glassy carbon electrode for amperometric detection of hydrogen peroxide

期刊

ANALYTICA CHIMICA ACTA
卷 632, 期 1, 页码 63-68

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.aca.2008.10.062

关键词

Dendrimer; Rhodium nanoparticles; Glassy carbon electrode; H(2)O(2) reduction; Cyclic voltammetry; Chronoamperometry

资金

  1. Humboldt fellowship
  2. Department of Science and Technology (DST), India

向作者/读者索取更多资源

Metallic nanoparticles of rhodium were prepared by using the newly synthesized N,N-bis-succinamide-based dendrimer as stabilizers. The Rh nanoparticles were spherical shaped with a particle size of similar to 2 nm. The dendrimer Rh-encapsulated nanoparticles (Rh-DENs) were immobilized on glassy carbon electrode (CCE) and their electrocatalytic activity towards hydrogen peroxide reduction was investigated using cyclic voltammetry and chronoamperometry. The Rh-DENs modified GCE showed excellent electrocatalytic activity for hydrogen peroxide reduction reactions. The steady-state cathodic current response of the modified electrode at -0.3 V (vs SCE) in phosphate buffer (pH 7.0) showed a linear response to hydrogen peroxide concentration ranging from 8 to 30 mu M with a detection limit and sensitivity of 5 mu M and 0.03103 x 10(-6) A mu M(-1), respectively. (C) 2008 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据