4.7 Article

Development and application of a multi-channel monitoring system for near real-time VOC measurement in a hazardous waste management facility

期刊

SCIENCE OF THE TOTAL ENVIRONMENT
卷 382, 期 2-3, 页码 364-374

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.scitotenv.2007.04.017

关键词

chemical bulking; multi-channel data logger system; PID sensor; volatile organic compounds; walk-in hood

向作者/读者索取更多资源

This paper describes the development and application of a multi-channel monitoring system for recording, processing, and analyzing volatile organic compound (VOC) levels discharged to the atmosphere from a walk-in hood in a hazardous waste management facility. The monitoring system consists of an array of PID (photo ionization detector) sensors and a networked control program that provides operational schematic diagram, performs data analyses, and illustrates real-time graphical displays. Furthermore, the system records potential worker exposures, exhaust filtration efficiency and environmental release levels. Multi-channel continuous monitoring of VOCs is successfully implemented during chemical bulking operations. It is shown that a real-time monitoring system is effective for early warning detection of hazardous chemicals and for predicting the performance of adsorption filters used for VOC removal. In addition, a connected local weather visualization system supports efforts to minimize potential health and environmental impacts of VOC emissions to surrounding areas. (c) 2007 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据