4.4 Article

Validity and Reproducibility of the Ergomo®Pro Power Meter Compared With the SRM and Powertap Power Meters

出版社

HUMAN KINETICS PUBL INC
DOI: 10.1123/ijspp.2.3.270

关键词

cycling; mobile power meter; comparison; field; laboratory

向作者/读者索取更多资源

Purpose: The Ergomo (R) Pro (EP) is a power meter that measures power output (PO) during outdoor and indoor cycling via 2 optoelectronic sensors located in the bottom bracket axis. The aim of this study was to determine the validity and the reproducibility of the EP compared with the SRM crank set and Powertap hub (PT). Method: The validity of the EP was tested in the laboratory during 8 submaximal incremental tests (PO: 100 to 400 W), eight 30-min submaximal constant-power tests (PO = 180 W), and 8 sprint tests (PO > 750 W) and in the field during 8 training sessions (time: 181 +/- 73 min; PO: similar to 140 to 150 W). The reproducibility was assessed by calculating the coefficient of PO variation (CV) during the submaximal incremental and constant tests. Results: The EP provided a significantly higher PO than the SRM and PT during the submaximal incremental test: The mean PO differences were +6.3% +/- 2.5% and +11.1% +/- 2.1%, respectively. The difference was greater during field training sessions (+12.0% +/- 5.7% and +16.5% +/- 5.9%) but lower during sprint tests (+1.6% +/- 2.5% and +3.2% +/- 2.7%). The reproducibility of the EP is lower than those of the SRM and PT (CV = 4.1% +/- 1.8%, 1.9% +/- 0.4%, and 2.1% +/- 0.8%, respectively). Conclusions: The EP power meter appears less valid and reliable than the SRM and PT systems.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据