We developed a new At Schottky CdTe pixel detector and measured its spectral performance. It has pixelated anodes made of aluminum and a common cathode made of platinum. Because of the low leakage current and the high bias voltage owing to the Schottky diode characteristic and the anode pixel configuration, a good spectral performance including a high energy resolution was achieved. When the pixel detector with a thickness of 0.75 mm was subjected to a bias voltage of 400 V and was operated at -20 degrees C, the full-width-half-maximum (FWHM) energy resolution of 1.1 and 1.8keV at 59.5 and 122keV, respectively, were successfully obtained. The spectral performance obtained with the At Schottky CdTe pixel detector exceeded that obtained with the conventional In Schottky CdTe pixel detector, which has an In common anode and Pt pixelated cathodes, under the same operating conditions.