4.6 Article

A sensitive, non-damaging electrochemiluminescent aptasensor via a low potential approach at DNA-modified gold electrodes

期刊

ANALYST
卷 136, 期 3, 页码 479-485

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/c0an00607f

关键词

-

资金

  1. National Nature Science Funding of China [90717104]
  2. Program for New Century Excellent Talents in University [NCET-06-0214]
  3. Chinese Ministry of Education
  4. National Basic Research Program of China (973 Program) [2011CB707703, 2007CB914100]
  5. State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences [SKLEAC2010004]

向作者/读者索取更多资源

Electrochemiluminescence (ECL)-based biosensors are often used in the field of DNA-and protein-assay. Although ruthenium complex-based ECL is sensitive, its high exciting potential may lead to oxidation damage to biomolecules. For the first time, a non-damaging, low potential ECL aptasensor was constructed for bioassay with lysozyme as a model. After a single-stranded anti-lysozyme aptamer was attached to a gold electrode, a double stranded (ds)-DNA formed with its complementary strand. Ru(phen)(3)(2+), as an ECL probe, was intercalated into the ds-DNA. The hybridization of lysozyme with its aptamer led to the dissociation of ds-DNA because of the high stability of the aptamer-lysozyme and therefore the Ru(phen)(3)(2+) intercalated into ds-DNA was released. A low potential ECL was observed at the ds-DNA-modified electrode because ds-DNA was able to preconcentrate tripropylamine (TPA) and acted as the acceptor of the protons released from protonated TPAH(+). While the DNA sequence (anti-lysozyme aptamer) was used as the special recognition element for lysozyme, the formed ds-DNA also provided a micro-environment for low potential ECL. The low potential ECL aptasensor achieved the determination of lysozyme with a detection limit of 0.45 pM. The day-to-day precision (RSDs, n = 5) for the determination of lysozyme was lower than 5%, showing the reliability of the aptasensor. The regeneration of the aptasensor confirmed that the low potential for ECL could decrease oxidation damage to biomolecules. Further, the proposed method was successfully used to analyze diluted egg white sample directly. The protocol exhibited a promising platform for sensitive bioassay and could be further applied for the development of other low potential ECL sensing systems.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据