4.6 Article

Fluorescence detection of trace PCB101 based on PITC immobilized on porous AAO membrane

期刊

ANALYST
卷 136, 期 2, 页码 278-281

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/c0an00510j

关键词

-

资金

  1. National Basic Research Program of China [2007CB936601]
  2. National natural Science Foundation of China [50972145, 50525207, 10975152]
  3. Chinese Academy of Science [KJCX2YWN341]

向作者/读者索取更多资源

A sensitive and selective fluorescent membrane for rapid detection of trace 2,2`,4,5,5`-pentachlorinated biphenyl (PCB101) has been achieved by immobilizing the fluorophore phenyl isothiocyanate (PITC) onto porous anodic aluminium oxide (AAO) membrane (denoted as PITC@AAO). The fluorescence of the PITC@AAO membrane is obviously enhanced after titrating the analyte PCB101 into the membrane, being ascribed to the halogen-bonding interaction between the fluorophore PITC and the analyte PCB101. The fluorescence intensity increases with the PCB101 concentration in the low range below 1 ppm, and there exists an approximate linear relationship between the relative fluorescence intensity and the PCB101 concentration in the low range of 1-6 ppb. Moreover, the PITC@AAO membrane shows good selectivity; for example, it is insensitive to common structural analogs (polychlorinated aromatics). The mechanisms of the fluorescence enhancement and the better sensitivity and selectivity of the PITC@AAO membrane to PCB101 than that of PITC/n-hexane solution are also discussed. This work demonstrates that trace (in ppb range) PCBs can be detected by simple fluorescence measurement.