4.6 Article

Temperature and concentration distribution within the Genius® dialysate container

期刊

NEPHROLOGY DIALYSIS TRANSPLANTATION
卷 22, 期 10, 页码 2962-2969

出版社

OXFORD UNIV PRESS
DOI: 10.1093/ndt/gfm356

关键词

dialysate contamination; dialysis efficiency; single-pass batch system; numerical simulations

向作者/读者索取更多资源

Background. The Genius(R) single-pass batch system, using a closed dialysate container, is increasingly applied for dialysis treatment. Although fluid separation between fresh and spent dialysate is maintained in the container during standard dialysis, dialysate mixing may occur under certain clinical conditions. An in vitro study showed that differences in dialysate temperature and solute content between fresh and spent dialysate determine the occurrence and moment of dialysate mixing. Methods. To better understand the maintenance of separation of fresh and spent dialysate in the prevention of mixing, a mathematical model of the 75 l Genius(R) container was developed and the general fluid, mass and heat transfer equations were solved, simulating a dialysis session of 300 min with 1 g/l urea as starting 'blood' urea concentration and 36.2 degrees C starting dialysate temperature. Boundary and initial conditions were chosen according to two different strategies applied in previous in vitro tests, with spontaneous cooling of the reservoir on the one hand and heating of the spent dialysate to maintain an equal temperature as the fresh dialysate on the other. Results. Our simulation data show that dialysate inside the container is cooling down near the container wall in both scenarios and near the central glass tube in the setup with spontaneous cooling. In the setup with heating of spent dialysate, the upper layers are heated near the central tube. Since density stratification is maintained at each time point, solutes will rise towards warmer zones. This is halfway between the container axis and wall for spontaneous cooling and, even to a larger extent, near the central tube for simulations with heated spent dialysate. Hence, the contaminated volume in the case of heating is much larger than theoretically supposed. Conclusions. These computer simulations unravel temperature and concentration distribution inside the container, offering insight into the complicated mixing phenomenon and indicate that temperature is a major impacting factor.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据