Corrosion zones of rebar in chloride contaminated concrete through potentiostatic study in concrete powder solution extracts

期刊

CORROSION SCIENCE
卷 49, 期 10, 页码 3935-3952

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.corsci.2007.05.003

关键词

concrete; steel; steel reinforced concrete; potentiostatic; polarization

向作者/读者索取更多资源

In this paper an experimental investigation has been carried out to identify semi-immune, active, passive and pitting zones of corrosion of the steel reinforcement in concrete powder solution extracts at different levels of admixed chloride. Potentiostatic linear sweeping test was carried out on three different types of steel reinforcement in the solution extracts made from concrete with three different types of cement at four levels of admixed chloride content with three w/c ratios for two test conditions, i.e., with and without deaeration. From the results obtained it was concluded that chloride content is the major factor in defining the zones of corrosion and the same was further confirmed through ANOVA. (c) 2007 Elsevier Ltd. All rights reserved.