期刊
CORROSION SCIENCE
卷 49, 期 10, 页码 3935-3952出版社
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.corsci.2007.05.003
关键词
concrete; steel; steel reinforced concrete; potentiostatic; polarization
In this paper an experimental investigation has been carried out to identify semi-immune, active, passive and pitting zones of corrosion of the steel reinforcement in concrete powder solution extracts at different levels of admixed chloride. Potentiostatic linear sweeping test was carried out on three different types of steel reinforcement in the solution extracts made from concrete with three different types of cement at four levels of admixed chloride content with three w/c ratios for two test conditions, i.e., with and without deaeration. From the results obtained it was concluded that chloride content is the major factor in defining the zones of corrosion and the same was further confirmed through ANOVA. (c) 2007 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐