A rapid diagnostic test for plague detects Yersinia pestis F1 antigen in ancient human remains.

期刊

COMPTES RENDUS BIOLOGIES
卷 330, 期 10, 页码 747-754

出版社

ELSEVIER FRANCE-EDITIONS SCIENTIFIQUES MEDICALES ELSEVIER
DOI: 10.1016/j.crvi.2007.07.007

关键词

RDT plague; Yersinia pestis; putative plague mass graves

类别

向作者/读者索取更多资源

A rapid diagnostic dipstick test (RDT) that detects Yersinia pestis F1 antigen has been recently applied on 18 putative plague victims exhumed from four archaeological burial sites in southeastern France dating back to the 16th, 17th and 18th centuries. The Y pestis antigen F1 was detected in 12 ancient samples out of 18 (67%). Negative controls confirmed their negativity (100%). Our results emphasize that the detection threshold of the RDT for plague (0.5 ng/ml) is sufficient for a first retrospective diagnosis of Y. pestis infection in ancient remains, and confirm the high specificity and sensitivity of the assay. Double-blind analyses performed by using two different techniques (RDT and 'suicide PCR') led us to the identification of the Y. pestis Fl antigen and the Y. pestis pla and gplD genes. These data provide clear evidence of the presence of Y. pestis in the examined specimens.