期刊
AMERICAN JOURNAL OF SPORTS MEDICINE
卷 35, 期 11, 页码 1922-1930出版社
SAGE PUBLICATIONS INC
DOI: 10.1177/0363546507304142
关键词
baseball; tennis; shoulder injury; clinical; overhead
Background: Posterior shoulder tightness with subsequent loss of humeral internal rotation range of motion has been linked to upper extremity lesions in overhead athletes. A valid clinical assessment is necessary to accurately identify posterior shoulder tightness as a contributor to injury. Purpose: To describe a modified supine assessment of posterior shoulder tightness by establishing the reliability, precision, clinical accuracy, and validity of the assessment. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: Intrasession, intersession, and intertester reliability and precision were established by comparing the commonly used side-lying assessment of posterior shoulder tightness and the described modified supine assessment. Clinical accuracy of both methods was obtained using an electromagnetic tracking device to track humeral and scapular motion. Construct validity was established by identifying posterior shoulder tightness in a group of overhead athletes (baseball pitchers and tennis players) reported in the literature to have limited humeral internal rotation and posterior shoulder tightness. Results: The side-lying intrasession intraclass correlation coeffecient (standard error of measurement), intersession intraclass correlation coeffecient (standard error of measurement), and intertester intraclass correlation coeffecient (standard error of measurement) were 0.83 cm (0.9), 0.42 cm (1.7), and 0.69 cm (1.4), respectively. The supine intrasession intraclass correlation coeffecient (standard error of measurement), intersession intraclass correlation coeffecient (standard error of measurement), and intertester intraclass correlation coeffecient (standard error of measurement) were 0.91 degrees (1.1 degrees), 0.75 degrees (1.8 degrees), and 0.94 degrees (1.8 degrees), respectively. In side-lying, the clinical accuracy expected was 0.9 +/- 0.6 cm of error while, when measured supine, it was 3.5 degrees +/- 2.8 degrees of error. Both assessments resulted in minimal scapular protraction (similar to 3.5 degrees). Between groups, baseball pitchers and tennis players had significantly less internal rotation range of motion (P <.0001) and greater posterior shoulder tightness (P =.004) when measured in supine, but not in side-lying (P =.312). Conclusion: Both methods resulted in good clinician accuracy and precision, suggesting that both can be performed accurately. The supine method can be assessed more reliably than side-lying between both sessions and testers. Clinical Relevance: Clinicians may want to consider use of the supine method given the higher reliability, validity, and similar precision and clinical accuracy.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据