4.5 Article

Improved Detection of Subendocardial Hyperenhancement in Myocardial Infarction Using Dark Blood-Pool Delayed Enhancement MRI

期刊

AMERICAN JOURNAL OF ROENTGENOLOGY
卷 196, 期 2, 页码 339-348

出版社

AMER ROENTGEN RAY SOC
DOI: 10.2214/AJR.10.4418

关键词

cardiac MRI; dark blood-pool delayed enhancement; delayed enhanced imaging; myocardial infarction

向作者/读者索取更多资源

OBJECTIVE. Delayed enhancement MRI using fast segmented k-space inversion recovery (IR) gradient-echo imaging is a well established bright-blood technique for identifying myocardial infarction and is used as the reference standard sequence in this study. The purpose of this study was to validate a recently developed dark blood-pool delayed enhancement technique in a porcine animal model, evaluate its performance in human patients, and quantify its performance compared with the reference standard in both. SUBJECTS AND METHODS. In an animal study, the reference standard and dark blood-pool delayed enhancement were assessed in three pigs with induced myocardial infarction. In a human study, 26 patients, 31-81 years old (19 men and seven women), with a known history of myocardial infarction were imaged using the reference standard and dark blood-pool delayed enhancement. Contrast-to-noise ratio (CNR), signal intensity ratio, signal-to-noise ratio (SNR), and qualitative scores of hyperenhancement were recorded. Measurements were compared using paired samples t test and Wilcoxon's signed rank test. RESULTS. In the animal study, the mean CNR of infarct to blood pool was 11 times higher for dark blood-pool delayed enhancement than for the reference standard. The mean SNR was 4.4 times higher for the reference standard. In the human study, the mean CNR and signal intensity ratio of hyperenhancing myocardium to the blood pool were 1.9 (p = 0.04) and 5.5 (p < 0.01) times higher, respectively, for dark blood-pool delayed enhancement compared with reference standard. The mean CNR and signal intensity ratio of hyperenhancing myocardium to normal myocardium and SNR were 2.8 (p < 0.01), 1.3 (p = 0.07), and 2.8 (p < 0.01) higher, respectively, for the reference standard. Qualitative analysis identified seven extra segments with grade 1 scars using dark blood-pool delayed enhancement (p < 0.01). CONCLUSION. Dark blood-pool delayed enhancement is complementary to the reference standard. It can detect more subendocardial foci of hyperenhancement, thus potentially identifying more infarcts and changing patient management.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据