4.5 Article

Three-Dimensional MDCT for Preoperative Local Staging of Gastric Cancer Using Gas and Water Distention Methods: A Retrospective Cohort Study

期刊

AMERICAN JOURNAL OF ROENTGENOLOGY
卷 195, 期 6, 页码 1316-1323

出版社

AMER ROENTGEN RAY SOC
DOI: 10.2214/AJR.10.4320

关键词

3D reconstruction; CT; MDCT; neoplasm; oral contrastagent; stomach; surface shaded display

资金

  1. Konkuk University Medical Center

向作者/读者索取更多资源

OBJECTIVE. The purpose of this article is to compare the T-staging accuracy and lesion detectability of MDCT with gas distention versus water distention according to the surgical and histopathologic findings, for the preoperative evaluation of gastric cancer. MATERIALS AND METHODS. For a 3-month period, 113 consecutive patients (72 men and 41 women; age range, 23-85 years; mean age, 58 years) with 116 surgically confirmed gastric cancers from a single institution were included in our study. All patients had undergone preoperative MDCT with either effervescent granules taken orally (n = 55) or after having drunk 1,000 mL of tap water (n = 58) to create gastric distention. In addition to transverse images, multiplanar reformation images and 3D surface shaded display images were also obtained with gas distention CT, and multiplanar reformation images were obtained with water distention CT. The CT images were retrospectively reviewed by two abdominal radiologists separately with regard to T staging and lesion detectability. The accuracy values were compared between the two methods using Fisher's exact test. RESULTS. The T-staging accuracy for gastric cancer did not differ significantly between gas distention and water distention CT scans, according to both radiologists (p > 0.05). Furthermore, the staging accuracy values for T1a cancers on gas distention CT scans for radiologists 1 and 2 were also comparable with those of water distention CT scans (91.1% vs 85% for radiologist 1 and 89.3% vs 85% for radiologist 2; p > 0.05). However, the tumor detection rate was significantly higher on gas distention CT scans using 2D and surface shaded display images for both radiologists (94.6% for radiologist 1 and 91.1% for radiologist 2), compared with the rates for water distention CT scans (78.3% and 73.3%) or gas distention CT scans using only 2D images (75.0% and 67.9%) (p < 0.05). CONCLUSION. MDCT using the gas distention technique showed performance comparable to that of the water distention technique for the T staging of preoperative gastric cancer with better lesion detectability.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据