4.7 Article

Evaluation of Continuous Positive Airway Pressure Therapy on Renin-Angiotensin System Activity in Obstructive Sleep Apnea

出版社

AMER THORACIC SOC
DOI: 10.1164/rccm.201403-0526OC

关键词

continuous positive airway pressure; nocturnal hypoxemia; obstructive sleep apnea; renal hemodynamics; renin-angiotensin system

资金

  1. Alberta Innovates-Health Solutions
  2. Cosmopolitan International Club of Calgary Graduate Scholarship
  3. American Society of Nephrology Student Scholar Grant
  4. Foothills Medical Centre Sleep Centre Development Fund
  5. Canadian Institute of Health Research
  6. joint initiative of Alberta Health and Wellness, the University of Alberta
  7. University of Calgary

向作者/读者索取更多资源

Rationale: Obstructive sleep apnea (OSA) has been associated with kidney function loss, which may be related to changes in the renin-angiotensin system (RAS). Objectives: We sought to determine the effect of, continuous positive airway pressure (CPAP) of patients with OSA on renal hemodynamics at baseline and in response to angiotensin II (AngII), which reflects RAS activity. Methods: Twenty normotensive, nondiabetic, newly diagnosed OSA subjects (15 men, 5 women, 50 +/- 2 yr, respiratory disturbance index [RDI] > 15 h(-1)) with nocturnal hypoxemia (Sa(O2) < 90% for >12% of the night) were studied in high-salt balance pre- and post-CPAP therapy (>4 h CPAP use/night for 1 mo). Glomerular filtration rate (GFR), renal plasma flow (RPF), and filtration fraction (FF) (a surrogate marker for intraglomerular pressure) were measured pre- and post-CPAP using inulin and para-aminohippurate clearance techniques at baseline and in response to graded AngII infusion (3 ng/kg/min X 30 min and 6 ng/kg/min X 30 min, respectively). Measurements and Main Results: CPAP corrected OSA and hypoxemia (RDI: 42 +/- 4 vs. 4 +/- 1 h(-1) P < 0.001; duration Sa(O2) < 90%: 36% +/- 5% vs. 6 +/- 2%, P < 0.001). CPAP reduced GFR (124 +/- 8 ml/min vs. 110 +/- 6 ml/min, P = 0.014), increased RPF (692 +/- 36 ml/min vs. 749 +/- 40 ml/min, P = 0.059), and reduced baseline FF (18.9 +/- 1.6% vs. 15.3 +/- 1.0%, P = 0.004). Post-CPAP demonstrated a blunted GFR response (-9 +/- 3 ml/min vs. -2 +/- 2 ml/min, P = 0.033) and augmented RPF response (-182 +/- 22 ml/min vs. -219 +/- 25 ml/min, P = 0.024) to AngII. FF response was maintained (P = 0.4). CPAP reduced baseline mean arterial pressure (94 +/- 2 vs. 89 +/- 2 mm Hg, P = 0.002), plasma aldosterone (149 +/- 18 vs. 109 +/- 10 pmol/L, P = 0003), and urinary protein excretion (61 [39-341] mg/day vs. 56 [22-204] mg/d, P = 0.003). Conclusions: CPAP therapy was associated with improved renal hemodynamics and down-regulation of renal RAS activity, suggesting a potential therapeutic benefit for kidney function.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据