Experimental evaluation of pairs of inline tubes of different size as components for heat exchanger tube bundles

期刊

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijheatmasstransfer.2015.06.047

关键词

Heat exchanger; Tube bundle; Unequal tube diameters; Fouling; Pressure drop

向作者/读者索取更多资源

A passive heat exchanger design for process intensification, reduced flow fluctuations, pressure-drop and fouling is evaluated experimentally. A primal geometry of two unequally sized cylinders placed in tandem arrangement under cross-flow is initially examined in order to establish the effect on the wake fluctuations, compared to the single cylinder case. Three pairs of cylinders were considered with a diameter ratio of d/D = 0.5 and at different longitudinal pitches, S-L/D = 1.5, 2.0 and 2.5, at the subcritical Reynolds number of Re-D = 3900. The streamwise velocity fluctuations in the wake of the cylinders were found to be lower for the cylinder pairs as compared to the case of the single cylinder. The preferred primal arrangement with unequally sized cylinders was extended to form a heat exchanger tube bundle, where the effect of the transverse distance between the tubes (S-T/D) was also studied. Three tube bundle configurations were examined with d/D = 0.5, S-L/D = 1.5 and S-T/D = 3.6 and S-T/D = 2.5, and a common arrangement with d/D = 1.0, S-L/D =2.5 and S-T/D=3.6. Measurements were performed with regard to the heat transfer on the external surface of the tubes and the pressure drop across each configuration. When compared to the conventional tube bundle arrangement, the arrangement with d/D = 0.5, S-L/D = 1.5 and S-T/D = 3.6 led to specific (per unit volume) heat transfer enhancement by 40% with indications of a negligible penalty in pressure drop. (C) 2015 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据