4.2 Article

A Randomized Controlled Trial of Plastic Drape for Prevention of Hypothermia during Umbilical Catheterization

期刊

AMERICAN JOURNAL OF PERINATOLOGY
卷 30, 期 10, 页码 839-842

出版社

THIEME MEDICAL PUBL INC
DOI: 10.1055/s-0033-1333670

关键词

hypothermia; prevention; umbilical catheterization; neonates

向作者/读者索取更多资源

Objective To determine the efficacy of polyethylene plastic draping in preventing hypothermia during umbilical catheterization. Methods A randomized controlled trial was conducted in newborns who required umbilical catheterization. A sterile polyethylene plastic sheet covering the procedural field was used in the plastic group, and a sterile conventional cotton drape was used in the control group. Results Sixty infants were enrolled and randomly assigned to the plastic group (n = 30) and control group (n = 30). There were no significant differences in the baseline demographic data. The use of plastic drapes was associated with a higher rectal temperature compared with the control group. Incidence of hypothermia at the end of procedure were 20% and 50% in the plastic group and control group, respectively (p = 0.03). Conclusion Polyethylene plastic draping was superior to conventional cloth draping in maintaining rectal temperature and preventing hypothermia during umbilical catheterization.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据