4.6 Article

Effect of Fluid Management Guided by Bioimpedance Spectroscopy on Cardiovascular Parameters in Hemodialysis Patients: A Randomized Controlled Trial

期刊

AMERICAN JOURNAL OF KIDNEY DISEASES
卷 61, 期 6, 页码 957-965

出版社

W B SAUNDERS CO-ELSEVIER INC
DOI: 10.1053/j.ajkd.2012.12.017

关键词

Bioimpedance spectroscopy; hemodialysis; hypervolemia; fluid overload; left ventricular hypertrophy

资金

  1. European Nephrology and Dialysis Institute

向作者/读者索取更多资源

Background: Fluid overload is the main determinant of hypertension and left ventricular hypertrophy in hemodialysis patients. However, assessment of fluid overload can be difficult in clinical practice. We investigated whether objective measurement of fluid overload with bioimpedance spectroscopy is helpful in optimizing fluid status. Study Design: Prospective, randomized, and controlled study. Setting & Participants: 156 hemodialysis patients from 2 centers were randomly assigned to 2 groups. Intervention: Dry weight was assessed by routine clinical practice and fluid overload was assessed by bioimpedance spectroscopy in both groups. In the intervention group (n = 78), fluid overload information was provided to treating physicians and used to adjust fluid removal during dialysis. In the control group (n = 78), fluid overload information was not provided to treating physicians and fluid removal during dialysis was adjusted according to usual clinical practice. Outcomes: The primary outcome was regression of left ventricular mass index during a 1-year follow-up. Improvement in blood pressure and left atrial volume were the main secondary outcomes. Changes in arterial stiffness parameters were additional outcomes. Measurements: Fluid overload was assessed twice monthly in the intervention group and every 3 months in the control group before the mid-or end-week hemodialysis session. Echocardiography, 48-hour ambulatory blood pressure measurement, and pulse wave analysis were performed at baseline and 12 months. Results: Baseline fluid overload parameters in the intervention and control groups were 1.45 +/- 1.11 (SD) and 1.44 +/- 1.12 L, respectively (P = 0.7). Time-averaged fluid overload values significantly decreased in the intervention group (mean difference, -0.5 +/- 0.8 L), but not in the control group (mean difference, 0.1 +/- 1.2 L), and the mean difference between groups was -0.5 L (95% CI, -0.8 to -0.2; P = 0.001). Left ventricular mass index regressed from 131 +/- 36 to 116 +/- 29 g/m(2) (P < 0.001) in the intervention group, but not in the control group (121 +/- 35 to 120 +/- 30 g/m(2); P = 0.9); mean difference between groups was -10.2 g/m(2) (95% CI, -19.2 to -1.17 g/m(2); P = 0.04). In addition, values for left atrial volume index, blood pressure, and arterial stiffness parameters decreased in the intervention group, but not in the control group. Limitations: Ambulatory blood pressure data were not available for all patients. Conclusions: Assessment of fluid overload with bioimpedance spectroscopy provides better management of fluid status, leading to regression of left ventricular mass index, decrease in blood pressure, and improvement in arterial stiffness. (c) 2013 by the National Kidney Foundation, Inc.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据