4.5 Article Proceedings Paper

Single pulse laser-induced breakdown spectroscopy of bulk aqueous solutions at oceanic pressures: interrelationship of gate delay and pulse energy

期刊

APPLIED OPTICS
卷 47, 期 31, 页码 G122-G130

出版社

OPTICAL SOC AMER
DOI: 10.1364/AO.47.00G122

关键词

-

类别

向作者/读者索取更多资源

The ability of oceanographers to make sustained measurements of ocean processes is limited by the number of available sensors for long-term in situ. analysis. In recent years, laser-induced breakdown spectroscopy (LIBS) has been identified as a viable technique to develop into an oceanic chemical sensor. We performed single pulse laser-induced breakdown spectroscopy of high pressure bulk aqueous solutions to detect three analytes (sodium, manganese, and calcium) that are of key importance in hydrothermal vent fluids, an ocean environment that would greatly benefit from the development of an oceanic LIBS sensor. The interrelationship of the key experimental parameters, pulse energy and gate delay, for a range of pressures up to 2.76 x 10(7) Pa, is studied. A minimal effect of pressure on the peak intensity is observed. A short gate delay (less than 200 ns) must be used at all pressures. The ability to use a relatively low laser pulse energy (less than approximate to 60 mJ) for detection of analytes at high pressure is also established. Na, Mn, and Ca are detectable at pressures up to 2.76 x 10(7) Pa at 50, 500, and 50 ppm, respectively, using an Echelle spectrometer. (C) 2008 Optical Society of America

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据