4.2 Article

3D finite element modeling of epiretinal stimulation: Impact of prosthetic electrode size and distance from the retina

期刊

INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS
卷 38, 期 5, 页码 277-287

出版社

WICHTIG PUBL
DOI: 10.5301/ijao.5000412

关键词

Multi-layer retina model; Threshold current; Electrode safety; Effective excitation area; Potential spatial resolution

资金

  1. National Basic Research Programs of China [2011CB013304/2013CB329401/2011CB707505]
  2. SJTU SMC-Morning Star Excellent Young Scholar-B [14X100010047]
  3. Medical-Engineering Cross Project of Shanghai Jiao Tong University [YG2013MS76]
  4. Research Grants Council of the Hong Kong Special Administrative Region, China [CityU123412]

向作者/读者索取更多资源

Purpose: A novel 3-dimensional (3D) finite element model was established to systematically investigate the impact of the diameter (F) of disc electrodes and the electrode-to-retina distance on the effectiveness of stimulation. Methods: The 3D finite element model was established based on a disc platinum stimulating electrode and a 6-layered retinal structure. The ground electrode was placed in the extraocular space in direct attachment with sclera and treated as a distant return electrode. An established criterion of electric-field strength of 1000 Vm(-1) was adopted as the activation threshold for RGCs. Results: The threshold current (TC) increased linearly with increasing F and electrode-to-retina distance and remained almost unchanged with further increases in diameter. However, the threshold charge density (TCD) increased dramatically with decreasing electrode diameter. TCD exceeded the electrode safety limit for an electrode diameter of 50 mu m at an electrode-to-retina distance of 50 to 200 mu m. The electric field distributions illustrated that smaller electrode diameters and shorter electrode-to-retina distances were preferred due to more localized excitation of RGC area under stimulation of different threshold currents in terms of varied electrode size and electrode-to-retina distances. Under the condition of same-amplitude current stimulation, a large electrode exhibited an improved potential spatial selectivity at large electrode-to-retina distances. Conclusions: Modeling results were consistent with those reported in animal electrophysiological experiments and clinical trials, validating the 3D finite element model of epiretinal stimulation. The computational model proved to be useful in optimizing the design of an epiretinal stimulating electrode for prosthesis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据