4.5 Article

Strain sensor based on a pair of single-mode-multimode-single-mode fiber structures in a ratiometric power measurement scheme

期刊

APPLIED OPTICS
卷 49, 期 3, 页码 536-541

出版社

OPTICAL SOC AMER
DOI: 10.1364/AO.49.000536

关键词

-

类别

向作者/读者索取更多资源

The strain and temperature dependencies of a step-index single-mode-multimode-single-mode (SMS) fiber structure are investigated numerically and experimentally. For intensity-based strain measurement using a single SMS fiber structure, at a selected wavelength, it is found that there is a high strain dependence, but also a temperature dependence that will induce strain measurement error. To minimize the temperature-induced strain measurement error, two SMS fiber structures are proposed and demonstrated in a ratiometric power measurement scheme; one SMS structure acts as the strain sensor, and the other SMS structure acts as the temperature monitor. The extracted temperature information is used to determine a strain value based on a suitable calibration of strain responses with temperature variations. It is demonstrated that for strain measurement from 0 to 1000 mu epsilon within the temperature range from 10 degrees C to 40 degrees C, the proposed configuration can provide a strain and temperature resolution of 0.34 mu epsilon and 0.14 degrees C, respectively, with a temperature-induced strain measurement error as low as 0.39 mu epsilon. (C) 2010 Optical Society of America