4.5 Article

Use of weekly, low dose, high frequency ultrasound for hard to heal venous leg ulcers: the VenUS III randomised controlled trial

期刊

BMJ-BRITISH MEDICAL JOURNAL
卷 342, 期 -, 页码 -

出版社

BMJ PUBLISHING GROUP
DOI: 10.1136/bmj.d1092

关键词

-

资金

  1. UK National Institute for Health Research (NIHR) [02/37/03]
  2. National Institute for Health Research [02/37/03] Funding Source: researchfish

向作者/读者索取更多资源

Objective To assess the clinical effectiveness of weekly delivery of low dose, high frequency therapeutic ultrasound in conjunction with standard care for hard to heal venous leg ulcers. Design Multicentre, pragmatic, two arm randomised controlled trial. Setting Community and district nurse led services, community leg ulcer clinics, and hospital outpatient leg ulcer clinics in 12 urban and rural settings (11 in the United Kingdom and one in the Republic of Ireland). Participants 337 patients with at least one venous leg ulcer of >6 months' duration or >5 cm(2) area and an ankle brachial pressure index of >= 0.8. Interventions Weekly administration of low dose, high frequency ultrasound therapy (0.5 W/cm(2), 1 MHz, pulsed pattern of 1: 4) for up to 12 weeks plus standard care compared with standard care alone. Main outcome measures Primary outcome was time to healing of the largest eligible leg ulcer. Secondary outcomes were proportion of patients healed by 12 months, percentage and absolute change in ulcer size, proportion of time participants were ulcer-free, health related quality of life, and adverse events. Results The two groups showed no significant difference in the time to healing of the reference leg ulcer (log rank test, P=0.61). After adjustment for baseline ulcer area, baseline ulcer duration, use of compression bandaging, and study centre, there was still no evidence of a difference in time to healing (hazard ratio 0.99 (95% confidence interval 0.70 to 1.40), P=0.97). The median time to healing of the reference leg ulcer was inestimable. There was no significant difference between groups in the proportion of participants with all ulcers healed by 12 months (72/168 in ultrasound group v 78/169 in standard care group, P=0.39 for Fisher's exact test) nor in the change in ulcer size at four weeks by treatment group (model estimate 0.05 (95% CI -0.09 to 0.19)). There was no difference in time to complete healing of all ulcers (log rank test, P=0.61), with median time to healing of 328 days (95% CI 235 to inestimable) with standard care and 365 days (224 days to inestimable) with ultrasound. There was no evidence of a difference in rates of recurrence of healed ulcers (17/31 with ultrasound v 14/31 with standard care, P=0.68 for Fisher's exact test). There was no difference between the two groups in health related quality of life, both for the physical component score (model estimate 0.69 (-1.79 to 3.08)) and the mental component score (model estimate -0.93 (-3.30 to 1.44)), but there were significantly more adverse events in the ultrasound group (model estimate 0.30 (0.01 to 0.60)). There was a significant relation between time to ulcer healing and baseline ulcer area (hazard ratio 0.64 (0.55 to 0.75)) and baseline ulcer duration (hazard ratio 0.59 (0.50 to 0.71)), with larger and older ulcers taking longer to heal. In addition, those centres with high recruitment rates had the highest healing rates. Conclusions Low dose, high frequency ultrasound administered weekly for 12 weeks during dressing changes in addition to standard care did not increase ulcer healing rates, affect quality of life, or reduce ulcer recurrence.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据