4.8 Article

Bioactive polymer grafting onto titanium alloy surfaces

期刊

ACTA BIOMATERIALIA
卷 6, 期 2, 页码 667-675

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.actbio.2009.08.043

关键词

Titanium alloy; Bioactive polymers; Osteointegration; ToF-SIMS; XPS

资金

  1. US National Institutes of Health [EB-002027]

向作者/读者索取更多资源

Bioactive polymers bearing sulfonate (styrene sodium sulfonate, NaSS) and carboxylate (methylacrylic acid, MA) groups were grafted onto Ti6Al4V alloy surfaces by a two-step procedure. The Ti alloy surfaces were first chemically oxidized in a piranha solution and then directly subjected to radical polymerization at 70 degrees C in the absence of oxygen. The grafted surfaces were characterized by X-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectrometry (ToF-SIMS) and the toluidine blue colorimetric method. Toluidine blue results showed 1-5 mu g cm(-2) of polymer was grafted onto the oxidized Ti surfaces. Grafting resulted in a decrease in the XPS Ti and 0 signals from the underlying Ti substrate and a corresponding increase in the XPS C and S signals from the polymer layer. The ToF-SIMS intensities of the S- and SO- ions correlated linearly with the XPS atomic percent S concentrations and the ToF-SIMS intensity of the TiO3H2- ion correlated linearly with the XPS atomic per cent Ti concentration. Thus, the ToF-SIMS S- SO- and TiO3H2- intensities can be used to quantify the composition and amount of grafted polymer. ToF-SIMS also detected ions that were more characteristic of the polymer molecular structure (C6H4SO3- and C8H7SO3- from NaSS, C4H5O2- from MA), but the intensity of these peaks depended on the polymer thickness and composition. An in vitro cell culture test was carried out with human osteoblast-like cells to assess the influence of the grafted polymers on cell response. Cell adhesion after 30 min of incubation showed significant differences between the grafted and ungrafted surfaces. The NaSS grafted surfaces showed the highest degree of cell adhesion while the MA-NaSS grafted surfaces showed the lowest degree of cell adhesion. After 4 weeks in vivo in rabbit femoral bones, bone was observed to be in direct contact with all implants. The percentage of mineralized tissue around the implants was similar for NaSS grafted and non-grafted implants (59% and 57%). The MA-NaSS grafted implant exhibited a lower amount of mineralized tissue (47%). (C) 2009 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据