In recent years, Ti-Zr-Nb alloys have become increasingly attractive as biomedical implant materials. In the present communication, we report the formation of self-organized nanotube oxide layers on a Ti-28Zr-8Nb biomedical alloy surface in 1 M (NH4)(2)SO4 containing 0.25 M NH4F. The morphology of the nanotube layers (the diameter and the length) is affected by the electrochemical conditions used (applied potential and time). Under specific conditions oxide layers consisting of highly ordered nanotubes with a wide range of diameters and lengths can be formed, varying, respectively, from approx. 50 to 300 nm and from approx. 500 nm to 22 mu m. The present results are highly promising for this biomedical alloy, as the large surface area and the tunable nanoscale geometry of the surface oxide provide novel pathways for the interaction of the materials with biorelevant species, such as cells and proteins. (C) 2007 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.