4.8 Article

Tumor Accumulation of NIR Fluorescent PEG PLA Nanoparticles: Impact of Particle Size and Human Xenograft Tumor Model

期刊

ACS NANO
卷 5, 期 11, 页码 8710-8720

出版社

AMER CHEMICAL SOC
DOI: 10.1021/nn2026353

关键词

in vivo imaging; fluorescence imaging; AF4; PEG-PLA; nanoparticle; HT29; A2780

资金

  1. Federal State of Saxonia Anhalt [FKZ 3646A/0907]
  2. Deutsche Forschungs-gemeinschaft [LSM: INST 271/250-1]

向作者/读者索取更多资源

Cancer therapies are often terminated due to serious side effects of the drugs. The cause is the nonspecific distribution of chemotherapeutic agents to both cancerous and normal cells. Therefore, drug carriers which deliver their toxic cargo specific to cancer cells are needed. Size is one key parameter for the nanoparticle accumulation In tumor tissues. In the present study the influence of the size of biodegradable nanoparticles was investigated in detail, combining in vivo and ex vivo analysis with comprehensive particle size characterizations. Polyethylene glycol polyesters poly(lactide) block polymers were synthesized and used for the production of three defined, stable, and nontoxic near-infrared (NIR) dye-loaded nanoparticle batches. Size analysis based on asymmetrical field flow field fractionation coupled with multiangle laser light scattering and photon correlation spectroscopy (PCS) revealed narrow size distribution and permitted accurate size evaluations. Furthermore, this study demonstrates the constraints of particle size data only obtained by PCS. By the multispectral analysis of the Maestro in vivo imaging system the in vivo fate of the nanoparticles next to their accumulation in special red fluorescent DsRed2 expressing HT29 xenografts could be followed. This simultaneous imaging in addition to confocal microscopy studies revealed information about the accumulation characteristics of nanoparticles inside the tumor tissues. This knowledge was further combined with extended size-dependent fluorescence imaging studies at two different xenograft tumor types, the HT29 (colorectal carcinoma) and the A2780 (ovarian carcinoma) cell lines. The combination of two different size measurement methods allowed the characterization of the dependence of nanoparticle accumulation in the tumor on even rather small differences in the. nanoparticle size. While two nanoparticle batches (111 and 141 nm in diameter) accumulated efficiently in the human xenograft tumor tissue, the slightly bigger nanoparticles (diameter 166 nm) were rapidly eliminated by the liver.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据