4.8 Article

Nanostructured Porous Si Optical Biosensors: Effect of Thermal Oxidation on Their Performance and Properties

期刊

ACS APPLIED MATERIALS & INTERFACES
卷 6, 期 18, 页码 16049-16055

出版社

AMER CHEMICAL SOC
DOI: 10.1021/am503987j

关键词

biosensor; enzyme; nanostructure; porous Si; thermal oxidation; label free

资金

  1. Russell Berrie Nanotechnology Institute (RBNI)
  2. Lorry I. Lokey Center for Life Science and Engineering

向作者/读者索取更多资源

The influence of thermal oxidation conditions on the performance of porous Si optical biosensors used for label-free and real-time monitoring of enzymatic activity is studied. We compare three oxidation temperatures (400, 600, and 800 degrees C) and their effect on the enzyme immobilization efficiency and the intrinsic stability of the resulting oxidized porous Si (PSiO2), Fabry-Perot thin films. Importantly, we show that the thermal oxidation profoundly affects the biosensing performance in terms of greater optical sensitivity, by monitoring the catalytic activity of horseradish peroxidase and trypsin-immobilized PSiO2. Despite the significant decrease in porous volume and specific surface area (confirmed by nitrogen adsorption-desorption studies) with elevating the oxidation temperature, higher content and surface coverage of immobilized enzymes is attained. This in turn leads to greater optical stability and sensitivity of PSiO2 nanostructures. Specifically, films produced at 800 degrees C exhibit stable optical readout in aqueous buffers combined with superior biosensing performance. Thus, by proper control of the oxide layer formation, we can eliminate the aging effect, thus achieving efficient immobilization of different biomolecules, optical signal stability, and sensitivity.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据