4.8 Article

Target-Induced Conjunction of Split Aptamer Fragments and Assembly with a Water-Soluble Conjugated Polymer for Improved Protein Detection

期刊

ACS APPLIED MATERIALS & INTERFACES
卷 6, 期 5, 页码 3406-3412

出版社

AMER CHEMICAL SOC
DOI: 10.1021/am405550j

关键词

water-soluble conjugated polymer; aptamer; protein detection; Foster resonance energy transfer (FRET); G-quadruplex

资金

  1. National Basic Research Program of China [2009CB930601, 2012CB933301, 2012CB723402]
  2. National Natural Science Foundation of China [21005040, 51073078, 51173080, 21305070]
  3. Ministry of Education of China [IRT1148]
  4. Priority Academic Program Development of Jiangsu Higher Education Institutions (PAPD)
  5. Program of Scientific Innovation Research of College Graduate in Jiangsu Province [CXLX12_0468]

向作者/读者索取更多资源

Rapid and sensitive detection of proteins is crucial to biomedical research as well as clinical diagnosis. However, so far, most detection methods rely on antibody-with poor sensitivity. Herein, we developed a simple and sensitive fluorescence-based strategy for protein detection by based assays and are usually laborious and time-consuming, using split aptamer fragments and a water-soluble polycationic polymer (poly{[9,9-bis(6'-(N,N,N-diethylmethylammonium)hexyl)-2,7-fluorenylene ethynylene]-alt-co-[2,5-bis(3'-(N,N,N-diethylmethylammonium)-1'-oxapropyl)-1,4-phenylene] tetraiodide} (PFEP)). The thrombin-binding DNA aptamer was split into two fragments for target recognition. The PFEP with high fluorescence emission was used as energy donor to amplify the signal of dye-labeled DNA probe. In the absence of target, three DNA/PFEP complexes were formed via strong electrostatic interactions, resulting in efficient Foster resonance energy transfer (FRET) between two fluorophores. While the presence of target induces a conjunction of two split aptamer fragments to form G-quadruplex, and subsequent assemble with PFEP leading to the formation of G-quadruplex/thrombin/PFEP complex. The distance between the PFEP and dye increased due to protein's large size, leading to a remarkable decrease of the FRET signal. Compared with the intact aptamer, the use of shorter split aptamer fragments increases the possibility of forming G-quadruplex upon target. Thus, the rate of change of FRET signal before and after the addition of target improved significantly and a higher sensitivity (limit of detection (LOD) = 2 nM) was obtained. This strategy is superior in that it is rapid, has low cost and homogeneous detection, and does not need heating to avoid an unfavorable secondary structure of DNA probe. With further efforts, this method could be extended to a universal way for simple and sensitive detection of a variety of biomolecules.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据