4.8 Review

Sensors for Breath Testing: From Nanomaterials to Comprehensive Disease Detection

期刊

ACCOUNTS OF CHEMICAL RESEARCH
卷 47, 期 1, 页码 66-76

出版社

AMER CHEMICAL SOC
DOI: 10.1021/ar400070m

关键词

-

资金

  1. FP7-Health Program under the LCAOS [258868]
  2. FP7's ERC grant under DIAG-CANCER [256639]
  3. FP'7 Lung Cancer Artificial Olfactory System (LCAOS) partners

向作者/读者索取更多资源

The analysis of volatile organic compounds in exhaled breath samples represents a new frontier in medical diagnostics because it is a noninvasive and potentially inexpensive way to detect illnesses. Clinical trials with spectrometry and spectroscopy techniques, the standard Volatile-compound detection methods, have shown the potential for diagnosing illnesses including cancer, multiple sclerosis, Parkinson's disease, tuberculosis, diabetes, and more via breath tests. Unfortunately, this approach requires expensive equipment and high levels of expertise to operate the necessary instruments, and the tests must be done quickly and use preconcentration techniques, all of which impede its adoption. Sensing matrices based on nanomaterials are likely to become a clinical and laboratory diagnostic tool because they are significantly smaller, easier-to-use, and less expensive than spectrometry or spectroscopy. An ideal nanomaterial-based sensor for breath testing should be sensitive at very low concentrations of volatile organic compounds, even in the presence of environmental or physiological confounding factors. It should also respond rapidly and proportionately to small changes in concentration and provide a consistent output that is specific to a given volatile organic compound. When not in contact with the volatile organic compounds, the sensor should quickly return to its baseline state or be simple and inexpensive enough to be disposable. Several reviews have focused on the methodological, biochemical, and clinical aspects of breath analysis in attempts to bring breath testing closer to practice for comprehensive disease detection. This Account pays particular attention to the technological gaps and confounding factors that impede nanomaterial-sensor-based breath testing, in the hope of directing future research and development efforts towards the best possible approaches to overcome these obstacles. We discuss breath testing as a complex process involving numerous steps, each of which has several possible technological alternatives with advantages and drawbacks that might affect the performance of the nanomaterial-based sensors in a breath-testing system. With this in mind, we discuss how to choose nanomaterial-based sensors, considering the profile of the targeted breath markers and the possible limitations of the approach, and how to design the surrounding breath-Jesting setup. We also discuss how to tailor the dynamic range and selectivity of the applied sensors to detect the disease-related volatile organic compounds of interest. Finally, we describe approaches to overcome other obstacles by improving the sensing elements and the supporting techniques such as preconcentration and dehumidification.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据