4.6 Article

Convolutional Neural Networks with Template-Based Data Augmentation for Functional Lung Image Quantification

期刊

ACADEMIC RADIOLOGY
卷 26, 期 3, 页码 412-423

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.acra.2018.08.003

关键词

Advanced Normalization Tools; ANTsRNet; Hyperpolarized gas imaging; Neural networks; Proton lung MRI; U-net

资金

  1. National Heart, Lung, and Blood Institute of the National Institutes of Health [R01HL133889, R01HL109618, R44HL087550, R21HL129112]

向作者/读者索取更多资源

Rationale and Objectives: We propose an automated segmentation pipeline based on deep learning for proton lung MRI segmentation and ventilation-based quantification which improves on our previously reported methodologies in terms of computational efficiency while demonstrating accuracy and robustness. The large data requirement for the proposed framework is made possible by a novel template-based data augmentation strategy. Supporting this work is the open-source ANTsRNet-a growing repository of well-known deep learning architectures first introduced here. Materials and Methods: Deep convolutional neural network (CNN) models were constructed and trained using a custom multilabel Dice metric loss function and a novel template-based data augmentation strategy. Training (including template generation and data augmentation) employed 205 proton MR images and 73 functional lung MRI. Evaluation was performed using data sets of size 63 and 40 images, respectively. Results: Accuracy for CNN-based proton lung MRI segmentation (in terms of Dice overlap) was left lung: 0.93 +/- 0.03, right lung: 0.94 +/- 0.02, and whole lung: 0.94 +/- 0.02. Although slightly less accurate than our previously reported joint label fusion approach (left lung: 0.95 +/- 0.02, right lung: 0.96 +/- 0.01, and whole lung: 0.96 +/- 0.01), processing time is <1 second per subject for the proposed approach versus similar to 30 minutes per subject using joint label fusion. Accuracy for quantifying ventilation defects was determined based on a consensus labeling where average accuracy (Dice multilabel overlap of ventilation defect regions plus normal region) was 0.94 for the CNN method; 0.92 for our previously reported method; and 0.90, 0.92, and 0.94 for expert readers. Conclusion: The proposed framework yields accurate automated quantification in near real time. CNNs drastically reduce processing time after offline model construction and demonstrate significant future potential for facilitating quantitative analysis of functional lung MRI.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据