4.7 Article

Development of the SJTU Unfoldable Robotic System (SURS) for Single Port Laparoscopy

期刊

IEEE-ASME TRANSACTIONS ON MECHATRONICS
卷 20, 期 5, 页码 2133-2145

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TMECH.2014.2364625

关键词

Actuation compensation; continuum mechanism; kinematics; single-port laparoscopy (SPL); surgical robot

资金

  1. Global Research Outreach program of the Samsung Advanced Institute of Technology
  2. National Natural Science Foundation of China [51375295]
  3. Shanghai Rising-Star Program [14QA1402100]

向作者/读者索取更多资源

Single-port laparoscopy (SPL) has attracted continuous attention in the past decade due to the potential of generating better surgical outcomes than the traditional multiport laparoscopy. In order to ease the challenging surgical manipulation tasks using manual tools in SPL, several robotic systems were constructed to provide surgeons an intuitive way to operate. With possible improvements identified, the SJTU unfoldable robotic system (SURS) for SPL is developed for improved system specifications. The SURS can be deployed into abdomen through a phi 12-mm port in its folded configuration and can then be unfolded for dual-arm surgical interventions with onboard 3-D visual guidance. A few key design concepts which lead to the specification improvements are elaborated. The design descriptions, kinematics modeling, actuation compensations, and experimental characterizations are detailed to demonstrate the potentials of the SURS.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据