期刊
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY-IN PRACTICE
卷 6, 期 4, 页码 1257-1263出版社
ELSEVIER SCIENCE BV
DOI: 10.1016/j.jaip.2017.09.021
关键词
Anapen; Autoinjectors; Adrenaline pharmacokinetics; Anaphylaxis; Cardiovascular responses
资金
- Bioprojet
BACKGROUND: The administration of adrenaline is a life-saving intervention for anaphylactic reactions. However, it has been questioned whether the needle length of the autoinjectors is sufficient to achieve genuine intramuscular delivery and optimal bioavailability. OBJECTIVE: To assess the adequacy of Anapen, which has a relatively short needle length (10.5 mm), through a comparison of the depot localization, plasma pharmacokinetics, and cardiovascular responses of adrenaline delivered via Anapen versus a prefilled syringe with a 25.4-mm needle, which is generally used for intramuscular injections. METHODS: This randomized, open-label, crossover study compared the impact of adrenaline administration at 2 sites in the thigh of 18 normal weight male volunteers, using either Anapen or the prefilled syringe; in addition, we studied the treatment of 12 overweight women with Anapen. The depot depth was measured by ultrasonography, plasma adrenaline level was evaluated by ultra performance liquid chromatography-mass spectrometry (UPLC-MS), and heart rates were measured usinga Holter monitor. RESULTS: Intramuscular injections were given with both devices at both thigh sites in nonobese men, but not in overweight women. Adrenaline levels showed a double peak, with parallel changes in the heart rate. The first peak, of potential vital importance in anaphylaxis treatment, occurred at approximately 10 minutes postinjection, with maximum concentration and area under the curve significantly higher with Anapen than with prefilled syringes; the magnitude of the second peak did not differ among the various conditions. Unexpectedly, in overweight women treated with Anapen, the magnitude of the first peak was similar to that observed in men, despite the injection being subcutaneous, and the overall bioavailability was enhanced. CONCLUSIONS: Needle length and intramuscular injection are not absolute requirements for autoinjector efficacy, but the monitoring of injection location, biphasic adrenaline levels, and cardiovascular responses is important for the assessment of their therapeutic relevance in anaphylaxis. (C) 2017 The Authors. Published by Elsevier Inc. on behalf of the American Academy of Allergy, Asthma & Immunology. This is an open access article under the CC BY-NC-ND license.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据