4.4 Article

Comparison of Quality and Output of Different Optimal Perimetric Testing Approaches in Children With Glaucoma

期刊

JAMA OPHTHALMOLOGY
卷 136, 期 2, 页码 155-161

出版社

AMER MEDICAL ASSOC
DOI: 10.1001/jamaophthalmol.2017.5898

关键词

-

资金

  1. Guide Dogs for the Blind Association [OR2009-04e]
  2. National Institute for Health Research Biomedical Research Centres based at Moorfields Eye Hospital National Health Services Foundation Trust/University College London Institute of Ophthalmology
  3. University College London Great Ormond Street Institute of Child Health/Great Ormond Street Hospital National Health Services Foundation Trust
  4. National Institute for Health Research [NF-SI-0512-10101] Funding Source: researchfish

向作者/读者索取更多资源

IMPORTANCE There is limited evidence to support the development of guidance for visual field testing in children with glaucoma. OBJECTIVE To compare different static and combined static/kinetic perimetry approaches in children with glaucoma. DESIGN, SETTING, AND PARTICIPANTS Cross-sectional, observational study recruiting children prospectively between May 2013 and June 2015 at 2 tertiary specialist pediatric ophthalmology centers in London, England (Moorfields Eye Hospital and Great Ormond Street Hospital). The study included 65 children aged 5 to 15 years with glaucoma (108 affected eyes). MAIN OUTCOMES AND MEASURES A comparison of test quality and outcomes for static and combined static/kinetic techniques, with respect to ability to quantify glaucomatous loss. Children performed perimetric assessments using Humphrey static (Swedish Interactive Thresholding Algorithm 24-2 FAST) and Octopus combined static tendency-oriented perimetry/kinetic perimetry (isopter V4e, III4e, or I4e) in a single sitting, using standardized clinical protocols, administered by a single examiner. Information was collected about test duration, completion, and quality (using automated reliability indices and our qualitative Examiner-Based Assessment of Reliability score). Perimetry outputs were scored using the Aulhorn and Karmeyer classification. One affected eye in 19 participants was retested with Swedish Interactive Thresholding Algorithm 24-2 FAST and 24-2 standard algorithms. RESULTS Sixty-five children (33 girls [50.8%]), with a median age of 12 years (interquartile range, 9-14 years), were tested. Test quality (Examiner-Based Assessment of Reliability score) improved with increasing age for both Humphrey and Octopus strategies and were equivalent in children older than 10 years (McNemar test,chi(2) = 0.33; P = .56), but better-quality tests with Humphrey perimetry were achieved in younger children (McNemar test,chi(2) = 4.0; P = .05). Octopus and Humphrey static MD values worse than or equal to -6 dB showed disagreement (Bland-Altman, mean difference, -0.70; limit of agreement, -7.74 to 6.35) but were comparable when greater than this threshold (mean difference, -0.03; limit of agreement, -2.33 to 2.27). Visual field classification scores for static perimetry tests showed substantial agreement (linearly weighted., 0.79; 95% CI, 0.65-0.93), although 25 of 80 (31%) were graded with a more severe defect for Octopus static perimetry. Of the 7 severe cases of visual field loss (grade 5), 5 had lower kinetic than static classification scores. CONCLUSIONS AND RELEVANCE A simple static perimetry approach potentially yields high-quality results in children younger than 10 years. For children older than 10 years, without penalizing quality, the addition of kinetic perimetry enabled measurement of far-peripheral sensitivity, which is particularly useful in children with severe visual field restriction.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据