4.4 Article

Demagnetization Assessment of Fractional-Slot and Distributed Wound 6-Phase Permanent Magnet Machines

期刊

IEEE TRANSACTIONS ON MAGNETICS
卷 51, 期 6, 页码 -

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TMAG.2014.2380152

关键词

Demagnetization; distributed winding; electric vehicle (EV); fractional-slot winding; permanent magnet (PM) machines; short-circuit (SC) faults

向作者/读者索取更多资源

A 6-phase fractional-slot-per-pole-per-phase interior permanent magnet (IPM) machine having a novel topology of 18-slot, 8-pole and a 6-phase, 48-slot, 8-pole IPM with distributed windings, both designed for a segment-A electric vehicle, are assessed for the risk of partial irreversible demagnetization under various fault conditions. This paper describes a more accurate approach of demagnetization assessment based on 2-D transient finite-element analysis. It is shown that due to the presence of low-order space harmonics in the fractional-slot IPM machine, the demagnetization risks across all pole pairs are different. Compared with the distributed wound machine, the fraction-slot machine is less vulnerable to demagnetization due to relatively high winding inductance, although its demagnetized regions are not uniform in each pole. It is also shown that although the demagnetizing current of one 3-phase short-circuit (SC) is greater than that of 6-phase SC, the resultant demagnetization risk is lower than that of 6-phase SC in the fractional-slotmachine.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据