期刊
CONTACT LENS & ANTERIOR EYE
卷 41, 期 5, 页码 463-468出版社
ELSEVIER
DOI: 10.1016/j.clae.2018.05.002
关键词
Scleral lens; Cornea; Bullae; Hypoxia; Complications
资金
- Research to Prevent Blindness, New York, NY
With the increased fitting of scleral lenses by eye care practitioners, complications with lens wear need to be considered. Several prior studies have addressed complications specific to scleral lens wear and the incidence of hypoxia with extended wear, but few report the presence of epithelial bullae. This case series investigates three patients with differing ocular surface diseases, yet all developed transient epithelial bullae with concurrent large diameter scleral lens wear. These bullae appear to form due to weakened connections in the corneal epithelium at the level of basement membrane and Bowman's layer and flatten within minutes of lens removal. These bullae need to be further studied, as they can increase the patient's risk of epithelial defects, infections, and other complications in already compromised corneas.