4.7 Article

Propagation-based phase-contrast x-ray tomography of cochlea using a compact synchrotron source

期刊

SCIENTIFIC REPORTS
卷 8, 期 -, 页码 -

出版社

NATURE PUBLISHING GROUP
DOI: 10.1038/s41598-018-23144-5

关键词

-

资金

  1. excellence cluster 172 Molecular Physiology of the Brain/Microscopy at the nanometer range of the German science foundation
  2. OptoHear of the European Research Council
  3. DFG Gottfried Wilhelm Leibniz program
  4. TUM Institute for Advanced Study - German Excellence Initiative
  5. Center for Advanced Laser Applications (CALA)
  6. Technische Universitat Munchen Institute for Advanced Study - German Excellence Initiative
  7. European Union Seventh Framework Program [291763]
  8. European Union

向作者/读者索取更多资源

We demonstrate that phase retrieval and tomographic imaging at the organ level of small animals can be advantageously carried out using the monochromatic radiation emitted by a compact x-ray light source, without further optical elements apart from source and detector. This approach allows to carry out microtomography experiments which - due to the large performance gap with respect to conventional laboratory instruments - so far were usually limited to synchrotron sources. We demonstrate the potential by mapping the functional soft tissue within the guinea pig and marmoset cochlea, including in the latter case an electrical cochlear implant. We show how 3d microanatomical studies without dissection or microscopic imaging can enhance future research on cochlear implants.