4.6 Article

Fast Fourier Transform-Based Analysis of Second-Harmonic Generation Image in Keratoconic Cornea

期刊

INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE
卷 53, 期 7, 页码 3501-3507

出版社

ASSOC RESEARCH VISION OPHTHALMOLOGY INC
DOI: 10.1167/iovs.10-6697

关键词

-

资金

  1. National Science Council in Taiwan [NSC 99-2221-E-002-096-MY3, 99-2221-E-002-096-MY3]
  2. National Health Research Institute (NHRI) in Taiwan [NHRI-EX100-10041EI]
  3. National Taiwan University [NTU-99R70409]
  4. Center for Quantum Science and Engineering, National Taiwan University [CQSE-99R80870]
  5. Chang Gung Memorial Hospital [CMRP350841-4]

向作者/读者索取更多资源

PURPOSE. To qualify and quantify structural alterations in keratoconic corneas ex vivo by the use of second-harmonic generation (SHG) microscopy and two-dimensional fast Fourier transform (2D-FFT) analysis. METHODS. Two keratoconic and three normal human corneal specimens were imaged with a multiphoton microscope. Forward and backward second-harmonic generation images (FSHG and BSHG) of corneal stroma were obtained at high resolution and at different depths. The SHG images were further analyzed with a 2D-FFT algorithm to quantify the texture and orientation changes of collagen fibers. RESULTS. The results showed that the abnormality of collagen architecture was found through the whole layer of stroma. 2D-FFT analysis of SHG cornea images provided fiber orientation direction and an aspect ratio (AR) as a quantitative measure of fiber direction determination. It was found that for keratoconic cornea the average AR values are statistically greater than those of the normal cornea: 1.66 +/- 0.42 (Case I keratoconic cornea), 1.72 +/- 0.44 (Case II keratoconic cornea), and 1.34 +/- 0.16 (average of three normal human corneas). Furthermore, the fiber directions determined by 2D-FFT analysis of BSHG and FSHG images were strongly correlated for large AR values (AR > 2). CONCLUSIONS. The high correlation between FSHG and BSHG fiber direction for large AR values shows that BSHG imaging can provide qualitative and quantitative information of the extent of structural changes in a keratoconic cornea. The ability to use BSHG for diagnosing and monitoring stroma abnormalities, even when cornea transparency is retained, demonstrates the clinical potential of this method. (Invest Ophthalmol Vis Sci. 2012;53:3501-3507) DOI:10.1167/iovs.10-6697

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据