Reclaiming Aged Transformer Oil with Activated Bentonite and Enhancing Reclaimed and Fresh Transformer Oils with Antioxidants

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TDEI.2014.004094

关键词

Power transformer; transformer oil; antioxidants; dielectric; critical parameters

向作者/读者索取更多资源

Transformers are the vital units of power system and the major dielectric used in transformer is petroleum based mineral oil, which acts both as an insulating medium and potential coolant. This work focuses on reclaiming aged mineral oil using activated bentonite and enhancing the critical characteristics of reclaimed mineral oil and fresh transformer oil using antioxidants. The reclamation is carried by treating 500 ml aged mineral oil with 5 g activated bentonite quantity. Then the treated sample is mixed with different combinations of natural and synthetic antioxidants. The enhancement of fresh transformer oil is carried by adding multiple combinations of antioxidants with different mechanisms like free radical scavenging, metal chelating and synergism. The critical parameters like breakdown voltage, viscosity, flash point and fire point of the samples are calculated using ASTM and IEC specifications before and after adding antioxidants. The recorded parameters prove that the reclaimed aged mineral oil after added with high performance antioxidant combinations can perform superior than base fluids and can be reused in power transformers. Moreover the enhanced fresh transformer oil with antioxidants shows greater improvement and this technique could be possibly employed for reclamation (regenerating) and enhancement of waste insulating oils.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据