4.6 Article

Comprehensive Echocardiographic Assessment of Normal Transcatheter Valve Function

期刊

JACC-CARDIOVASCULAR IMAGING
卷 12, 期 1, 页码 25-34

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcmg.2018.04.010

关键词

echocardiography; effective orifice area; hemodynamics; transcatheter aortic valve replacement

资金

  1. Medtronic
  2. Edwards Lifesciences
  3. Abbott
  4. LivaNova
  5. Boston Scientific
  6. Edwards

向作者/读者索取更多资源

OBJECTIVES This study aims to establish parameters for identifying normal function for each of the 3 iterations of balloon-expandable valves and 2 iterations of self-expanding valves. BACKGROUND Expected transthoracic echocardiographic Doppler-derived hemodynamic data for transcatheter aortic valves inform pre-implant decision-making and post-implanted monitoring of longitudinal valve function. METHODS We collected the echocardiography core Lab measured mean gradients and effective orifice area (EOA) from discharge or 30-day echocardiograms from randomized trials; the PARTNER (Placement of Aortic Transcatheter Valves) trials for the balloon-expandable valves and the Medtronic CoreValve US Pivotal trial and Medtronic CoreValve Evolut R United States IDE Clinical Study for the self-expanding valves. RESULTS For all SAPIEN (Edwards Lifesciences, Irvine, California) valve sizes, mean EOA is 1.70 +/- 0.49 cm(2) with a mean gradient of 9.36 +/- 4.13 mm Hg. For all SAPIEN XT valve sizes, mean EOA is L67 +/- 0.46 cm(2) with a mean gradient of 9.52 +/- 3.64 mm Hg. For all SAPIEN 3 valve sizes, the mean EOA is 1.66 +/- 0.38 cm(2) with a mean gradient of 11.18 +/- 4.35 mm Hg. For all CoreValve valve sizes, the mean EOA is 1.88 +/- 0.56 cm(2) with a mean gradient of 8.85 +/- 4.14 mm Hg. For all Evolut R valve sizes, the mean EOA is 2.01 +/- 0.65 cm(2) with a mean gradient of 7.52 +/- 3.19 mm Hg. The SAPIEN 3 post-implant EOA was progressively larger for each quintile of baseline annular area by computed tomography (p < 0.001). Similarly, for the Evolut R valve, post-implantation EOA was significantly larger for each quintile of baseline annular perimeter (p < 0.001). CONCLUSIONS Tables of expected mean transcatheter aortic valve hemodynamics by valve type and size are essential in evaluating the function of these transcatheter prosthetic valves. Tables of expected EOA by the native annular anatomy may be useful for pre-implantation decision making. Criteria for defining structural valve dysfunction are proposed. (C) 2019 by the American College of Cardiology Foundation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据