4.7 Article

Experimental investigation and finite element analysis of web-stiffened cold formed lipped channel columns with batten sheets

期刊

THIN-WALLED STRUCTURES
卷 125, 期 -, 页码 38-50

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.tws.2018.01.006

关键词

Experimental investigation; Finite element analysis; Web-stiffened cold-formed lipped channel columns; Batten sheet; Ultimate strength; Buckling mode

资金

  1. National Natural Science Foundation of China - through the research project Theoretical and Experimental Study on Distortional Buckling and Its Interaction Buckling of Cold-formed Steel Thin-walled Members in Compression [50978128]

向作者/读者索取更多资源

This paper presents an experimental investigation and a finite element analysis on web-stiffened cold-formed lipped channel columns with batten sheets connected between the column's two lips at reasonable space. Initially, the paper presents the static compressive test results on 18 specimens under pinned-end restraint conditions with different column length and load eccentricities considered. It is shown that the batten sheets exert significant influence on both the buckling modes and the ultimate strength of the specimens under positive eccentric loading and/or axial loading conditions, while they just have few impacts on that of the specimens under negative eccentric compression. Strengthened by the batten sheets, the columns performed obviously higher ultimate strength under axial and positive eccentric compression compared with the ones without batten sheets and the strengthening effect increase with the increase of column length. Furthermore, the tested specimens were also numerically investigated by finite element program of ANSYS. Geometric and material nonlinearities were both included in the finite element models and it is demonstrated that the numerical analysis can closely predict the ultimate strength and the buckling behavior of the tested columns. Finally, a parametric study was conducted by using program of ANSYS, in which effect of the increasing lip stiffener width and varying batten sheet space were all investigated and it is concluded that the contribution of the batten sheets to the columns' strength decreased notably with the increasing lip width or batten sheets' space for axial and/or positive compressed columns. The best choice of the distance between batten sheets (d <= lambda/3) for axial compressed lipped channel columns must also be a reasonable choice for positive compressed columns.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据