4.7 Article

Ionic liquid ultrasound-assisted dispersive liquid-liquid microextraction based on solidification of the aqueous phase for preconcentration of heavy metals ions prior to determination by LC-UV

期刊

TALANTA
卷 182, 期 -, 页码 69-73

出版社

ELSEVIER
DOI: 10.1016/j.talanta.2018.01.060

关键词

Dispersive liquid-liquid microextraction; Heavy metals ions; Liquid chromatography; Phosphonium ionic liquid; Ultrasound energy

资金

  1. Polish Ministry of Science and Higher Education [03/31/DS-PB/0360]

向作者/读者索取更多资源

Ionic liquid ultrasound-assisted dispersive liquid-liquid microextraction based on solidification of the aqueous phase was used for preconcentration of Ni2+, Co2+, Cd2+, Cu2+, Pb2+ in natural water samples prior to liquid chromatography with UV detection. In the proposed method, the ammonium pyrrolidinedithiocarbamate was used as a complexing agent and the phosphonium ionic liquid trihexyl(tetradecyl)phosphonium bis[(2,4,4-trimethyl)pentyl]phosphinate (Cyphos IL 104) was used as an extractant. Ultrasound energy was used to disperse the extractant in the aqueous phase. After microextraction, the ionic liquid and aqueous phases were separated by centrifugation. Then the aqueous phase was frozen and the lighter than water ionic liquid phase containing metal ions complexes with pyrrolidinedithiocarbamate was separated and dissolved in a small volume of methanol prior to injection into the liquid chromatograph. Several parameters including the volume of extractant, the pH of the sample, the concentration of complexing agent, the time of ultrasound energy treatment, the time and speed of centrifugation and the effect of ionic strength were optimized. Under the optimized conditions (10 mu L of Cyphos IL 104, pH = 5, 0.3% w/v ammonium pyrrolidinedithiocarbamate, 60 s of ultrasound use, 5 min/5000 rpm (2516 xg) of centrifugation, 2.0 mg of NaCl), preconcentration factors were 211, 210, 209, 207 and 211 for Ni2+, Co2+, Cd2+, Cu2+ and Pb2+ respectively. Linearity was observed in the ranges 0.2-75.0 mu g L-1 for Pb2+, Cd2+, Co2+ and 0.5-100.0 mu g L-1 for Cu2+, Ni2+. The limits of detection were 0.03 mu g L-1 for Ni2+, 0.03 mu g L-1 for Co2+, 0.03 mu g L-1 for Cd2+, 0.02 mu g L-1 for Cu2+, 0.02 mu g L-1 for Pb2+, respectively. The accuracy of this method was evaluated by preconcentration and determination of Ni2+, Co2+, Cd2+, Cu2+, Pb2+ in certified reference materials (TMRAIN-04 and NIST 1643e) with the recovery values in the range of 97-102%. The presented method has been successfully applied for the determination of analytes in natural water samples (river and lake waters).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据