期刊
IEEE SENSORS JOURNAL
卷 15, 期 2, 页码 693-702出版社
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JSEN.2014.2352171
关键词
PLB; piezoelectric transducers; structural health monitoring; SHM; electromechanical; EMI; impedance
资金
- Sao Paulo Research Foundation (FAPESP) [2013/16434-0, 2012/10825-4]
- PROPe-UNESP
- Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP) [12/10825-4] Funding Source: FAPESP
The pencil lead break (PLB) is a well-known method for characterizing acoustic emission sensors. In this paper, we analyze the effectiveness of this method in characterizing piezoelectric transducers for structural health monitoring (SHM) systems based on the electromechanical impedance (EMI) technique. Tests were carried out on aluminum beams of different sizes, and two types of transducers were considered: 1) lead zirconate titanate ceramics and 2) macrofiber composite devices. The experimental results indicate a clear relationship between the variation in the electrical impedance signature of the transducer and power spectral density obtained with the PLB method. Therefore, the PLB can be a simple and effective method for assessing the sensitivity of transducers for damage detection in SHM systems based on the EMI technique.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐