4.7 Article

Detection of Volatile Organic Compounds Using Microwave Sensors

期刊

IEEE SENSORS JOURNAL
卷 15, 期 1, 页码 248-254

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JSEN.2014.2345477

关键词

Microwave resonator; PDMS swelling; resonance frequency

资金

  1. Canada Excellence Research Chairs Program

向作者/读者索取更多资源

A microwave (MW)-based sensing platform for detection of acetone vapor is demonstrated. The sensing platform comprises of an MW resonator coated with a thin layer of polydimethylsiloxane (PDMS) that acts as a sorbent layer for acetone. Absorption-induced swelling of PDMS changes the permittivity and results in reproducible variations in the resonance frequency of the resonator. Here, we demonstrate the detection of acetone, as the model analyte, with the concentrations of 0-265 ppt. In addition, since the technique is based on electromagnetic fields spilling into space, we show the ability of the sensor to detect acetone in a noncontact fashion.