4.7 Article

Electrodeposited nanoporous ruthenium oxide for simultaneous quantification of ascorbic acid and uric acid using chronoamperometry at two different potentials

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 255, 期 -, 页码 316-324

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2017.08.089

关键词

Electrodeposition; Ruthenium dioxide; Ascorbic acid; Uric acid; Nonenzymatic amperometric sensor

资金

  1. National Research Foundation of Korea (NRF) - Ministry of Science, ICT and Future Planning [2017R1A2B4002159, 2017R1A2A2A14001137]
  2. National Research Foundation of Korea [2017R1A2B4002159, 2017R1A2A2A14001137] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

Nanoporous ruthenium dioxide (RuO2) was simply prepared by electrodeposition with potential cycling in RuCl3 solution in the presence of reverse micelles of Triton X-100. The electrodeposited RuO2 on Au substrate electrode showed high electroactivity for the oxidations of L-ascorbic acid (AA) and uric acid (UA), while AA oxidation started from a less positive potential compared to UA oxidation. Simultaneous quantitative analysis of AA and UA was successfully carried out via chronoamperometric measurements at two different applied potentials using RuO2 deposited electrode. Due to the oxidation potential difference between AA and UA at RuO2\ electrode, only AA was oxidized at an applied potential of 0.20 V vs. SCE and both AA and UA were oxidized at 0.32 V vs. SCE. AA concentration was determined from the current measured at 0.20 V; and then UA concentration was estimated from the current measured at 0.32 V using the predetermined AA concentration. Electrodeposited nanoporous RuO2 electrode exhibited current responses linearly proportional to AA and UA concentrations in a wide concentration range (0-1 mM) and fast response time (<= 1 s). The current sensitivities were 342.8 perpendicular to 26.3 mu A mM(-1) cm(-2) for AA at 0.20 V; 377.8 +/- 18.4 mu AmM-1 cm(-2) for AA at 0.32 V; and 344.2 +/- 11.6 mu AmM-1 cm(-2) for UA at 0.32 V. In addition, Ru02 electrode showed a high selectivity over interferents such as 4-acetamidophenol (AP), dopamine (DA), and glucose. Reasonable stability and repeatability of RuO2 electrode were also confirmed. Selective quantification of AA and UA in an arbitrary mixture and a human urine sample demonstrated that RuO2 electrode has practical utility in real sample analysis with satisfactory results. (C) 2017 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据