4.7 Article

Highly sensitive label-free antibody detection using a long period fibre grating sensor

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 271, 期 -, 页码 24-32

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2018.05.109

关键词

Long period gratings; Biosensor; Layer-by-Layer techniques; Optical fibre sensor; Streptavidin; Human IgM

资金

  1. Engineering and Physical Sciences Research Council [EP/N026985/1, EP/N025725/1]
  2. EPSRC PhD studentship
  3. EPSRC [EP/N025725/1, EP/N026985/1] Funding Source: UKRI

向作者/读者索取更多资源

An optical fibre long period grating (LPG) biosensor is appealing in the detection of biomolecules because of the high sensitivity, label-free and real-time measurement. The miniaturized size, ability of remote sensing and immunity to electromagnetic interference of the LPG biosensor provide various possibility of single-point sensing in situations such as point of care diagnostics and in vivo measurement. Two optical fibre LPG based biosensors are reported for detection of streptavidin (SV) and immunoglobulin M (IgM) respectively. The LPG is coated with a film containing three layers of Poly(allylamine hydrochloride)/gold coated silica nanoparticles via the layer-by-layer method. Biotin is covalently bonded to the surface of the gold shell by means of the formation of an amide bonds for detection of streptavidin. The concentration of SV in water for detection varied from 1.25 nM to 2.7 mu M. The LPG sensor, operating close to the phase matching condition shows a high sensitivity of 3.88 (ng/ mm(2))(-1) and a detection limit of 0.86 mu g/mm(2) for the detection of SV. The limit of detection is 22 times lower than previously demonstrated with this type of sensor. The developed IgM sensor has the same configuration of film but has anti-IgM embedded on the LPG instead of biotin, demonstrating versatility of the sensing platform. This was used for the detection of human IgM with concentrations from 15.6 mu g/ml to 1 mg/ml. The LPG sensor exhibits a sensitivity of 11 nm (ng/mm(2))(-1) for the detection of IgM with a detection limit of 15 pg/mm(2). The developed highly sensitive IgM sensor shows the potential application of clinical point of care for detection of lower concentration of IgM in vitro. The proposed biosensor exhibits high sensitivity and rapid detection of low concentrations biomolecules from the small size of SV to the large size of IgM.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据