4.7 Article

Portable X-ray fluorescence for the detection of POP-BFRs in waste plastics

期刊

SCIENCE OF THE TOTAL ENVIRONMENT
卷 639, 期 -, 页码 49-57

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.scitotenv.2018.05.132

关键词

Waste plastics; LPCL screening; Quantification; PBDEs; HBCDD

资金

  1. Irish Environmental Protection Agency [2014-RE-MS-2]
  2. Environmental Protection Agency Ireland (EPA) [2014-RE-MS-2] Funding Source: Environmental Protection Agency Ireland (EPA)

向作者/读者索取更多资源

The purpose of this study was to establish the efficacy of portable X-ray fluorescence (XRF) instrumentation as a screening tool for a variety of end of life plastics which may contain excess amounts of brominated flame retardants (BFRs), in compliance with European Union (EU) and United Nations Environment Programme (UNEP) legislative limits (low POP concentration limits -LPCLs). 555 samples of waste plastics were collected from eight waste and recycling sites in Ireland, including waste electrical and electronic equipment (WEEE), textiles, polyurethane foams (PUFs), and expanded polystyrene foams. Samples were screened for bromine content, in situ using a Niton T XL3T GOLDD XRF analyser, the results of which were statistically compared to mass spectrometry (MS)-based measurements of polybrominated diphenyl ethers (PBDEs), hexabromocyclododecane (HBCDD) and tetrabromobisphenol-A (TBBP-A) concentrations in the same samples. Regression between XRF and MS for WEEE samples shows that, despite an overall favourable trend, large deviations occur for a cluster of samples indicative of other bromine-based compounds in some samples; even compensating for false-positives due to background interference from electronic components, XRF tends to over-estimate MS-determined BFR concentrations in the 100 to 10,000 mg kg-1 range. Substantial deviations were additionally found between results for PUFs, textiles and polystyrene samples, with the XRF overestimating BFR concentrations by a factor of up to 1.9; this is likely due tomatrix effects influencing XRFmeasurements. However, expanded (EPS) and extruded polystyrene (XPS) yielded much more reliable estimations of BFR-content due to a dominance of HBCDD in these materials. XRF provedmuchmore reliable as a pass/fail screening tool for LPCL compliance (including a prospective LPCL on Deca-BDE based on REACH). Using a conservative threshold of BFR content exceeding legislative limits (710 mg kg(-1) bromine attributed to Penta-BDE), XRF mistakenly identifies only 6 % of samples (34/555) as exceeding legislative limits. (C) 2018 Elsevier B. V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据