4.6 Article

Radiation efficiency of a depleted cobalt-60 source for products that require low radiation doses

期刊

RADIATION PHYSICS AND CHEMISTRY
卷 150, 期 -, 页码 169-171

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.radphyschem.2018.04.032

关键词

Cobalt-60; Garlic; GIP; Dose distribution; Fricke dosimeter

向作者/读者索取更多资源

To determine the radiation processing efficiency of a cobalt-60 source at the end of its useful life for products that require low radiation doses, the irradiation doses absorbed by the products were determined using the Fricke dosimeters and UV-visible spectrophotometer. Garlic Allium sativum L. was considered in this study because of its virtue in treating different diseases such as cancer and cardiovascular diseases and high cholesterol-lowering effect and the short time required for its irradiation. Therefore, boxes containing garlic were irradiated at 50, 100, and 150 Gy for 7, 18, and 29 min, respectively. The relative absorbed dose mapping showed a symmetrical distribution in the front and back sides of the garlic box. Thus, the cobalt-60 source was revealed to be efficient in the irradiation of garlic even at the end of its useful life.